Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
bioRxiv ; 2023 Sep 06.
Artigo em Inglês | MEDLINE | ID: mdl-37732196

RESUMO

Traditional methods for mapping cerebral blood flow (CBF), such as positron emission tomography and magnetic resonance imaging, offer only isolated snapshots of CBF due to scanner logistics. Speckle contrast optical tomography (SCOT) is a promising optical technique for mapping CBF. However, while SCOT has been established in mice, the method has not yet been demonstrated in humans - partly due to a lack of anatomical reconstruction methods and uncertainty over the optimal design parameters. Herein we develop SCOT reconstruction methods that leverage MRI-based anatomical head models and finite-element modeling of the SCOT forward problem (NIRFASTer). We then simulate SCOT for CBF perturbations to evaluate sensitivity of imaging performance to exposure time and SD-distances. We find image resolution comparable to intensity-based diffuse optical tomography at superficial cortical tissue depth (~1.5 cm). Localization errors can be reduced by including longer SD-measurements. With longer exposure times speckle contrast decreases, however, noise decreases faster, resulting in a net increase in SNR. Specifically, extending exposure time from 10µs to 10ms increased SCOT SNR by 1000X. Overall, our modeling methods provide anatomically-based image reconstructions that can be used to evaluate a broad range of tissue conditions, measurement parameters, and noise sources and inform SCOT system design.

2.
bioRxiv ; 2023 Aug 04.
Artigo em Inglês | MEDLINE | ID: mdl-37577491

RESUMO

Diffuse optical methods including speckle contrast optical spectroscopy and tomography (SCOS and SCOT), use speckle contrast (κ) to measure deep blood flow. In order to design practical systems, parameters such as signal-to-noise ratio (SNR) and the effects of limited sampling of statistical quantities, should be considered. To that end, we have developed a method for simulating speckle contrast signals including effects of detector noise. The method was validated experimentally, and the simulations were used to study the effects of physical and experimental parameters on the accuracy and precision of κ. These results revealed that systematic detector effects resulted in decreased accuracy and precision of κ in the regime of low detected signals. The method can provide guidelines for the design and usage of SCOS and/or SCOT instruments.

3.
Opt Lett ; 48(6): 1427-1430, 2023 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-36946944

RESUMO

Speckle contrast optical spectroscopy/tomography (SCOS/T) provides a real-time, non-invasive, and cost-efficient optical imaging approach to mapping of cerebral blood flow. By measuring many speckles (n>>10), SCOS/T has an increased signal-to-noise ratio relative to diffuse correlation spectroscopy, which measures one or a few speckles. However, the current free-space SCOS/T designs are not ideal for large field-of-view imaging in humans because the curved head contour cannot be readily imaged with a single flat sensor and hair obstructs optical access. Herein, we evaluate the feasibility of using cost-efficient multi-mode fiber (MMF) bundles for use in SCOS/T systems. One challenge with speckle contrast measurements is the potential for confounding noise sources (e.g., shot noise, readout noise) which contribute to the standard deviation measure and corrupt the speckle contrast measure that is central to the SCOS/T systems. However, for true speckle measurements, the histogram of pixel intensities from light interference follows a non-Gaussian distribution, specifically a gamma distribution with non-zero skew, whereas most noise sources have pixel intensity distributions that are Gaussian. By evaluating speckle data from static and dynamic targets imaged through an MMF, we use histograms and statistical analysis of pixel histograms to evaluate whether the statistical properties of the speckles are retained. We show that flow-based speckle can be distinguished from static speckle and from sources of system noise through measures of skew in the pixel intensity histograms. Finally, we illustrate in humans that MMF bundles relay blood flow information.

4.
BMC Neurol ; 21(1): 154, 2021 Apr 09.
Artigo em Inglês | MEDLINE | ID: mdl-33836684

RESUMO

BACKGROUND: The cortical microvascular cerebral blood flow response (CBF) to different changes in head-of-bed (HOB) position has been shown to be altered in acute ischemic stroke (AIS) by diffuse correlation spectroscopy (DCS) technique. However, the relationship between these relative ΔCBF changes and associated systemic blood pressure changes has not been studied, even though blood pressure is a major driver of cerebral blood flow. METHODS: Transcranial DCS data from four studies measuring bilateral frontal microvascular cerebral blood flow in healthy controls (n = 15), patients with asymptomatic severe internal carotid artery stenosis (ICA, n = 27), and patients with acute ischemic stroke (AIS, n = 72) were aggregated. DCS-measured CBF was measured in response to a short head-of-bed (HOB) position manipulation protocol (supine/elevated/supine, 5 min at each position). In a sub-group (AIS, n = 26; ICA, n = 14; control, n = 15), mean arterial pressure (MAP) was measured dynamically during the protocol. RESULTS: After elevated positioning, DCS CBF returned to baseline supine values in controls (p = 0.890) but not in patients with AIS (9.6% [6.0,13.3], mean 95% CI, p < 0.001) or ICA stenosis (8.6% [3.1,14.0], p = 0.003)). MAP in AIS patients did not return to baseline values (2.6 mmHg [0.5, 4.7], p = 0.018), but in ICA stenosis patients and controls did. Instead ipsilesional but not contralesional CBF was correlated with MAP (AIS 6.0%/mmHg [- 2.4,14.3], p = 0.038; ICA stenosis 11.0%/mmHg [2.4,19.5], p < 0.001). CONCLUSIONS: The observed associations between ipsilateral CBF and MAP suggest that short HOB position changes may elicit deficits in cerebral autoregulation in cerebrovascular disorders. Additional research is required to further characterize this phenomenon.


Assuntos
Pressão Arterial , Estenose das Carótidas/fisiopatologia , Circulação Cerebrovascular , AVC Isquêmico/fisiopatologia , Decúbito Dorsal/fisiologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Velocidade do Fluxo Sanguíneo/fisiologia , Pressão Sanguínea , Isquemia Encefálica/fisiopatologia , Estudos de Casos e Controles , Feminino , Decúbito Inclinado com Rebaixamento da Cabeça/fisiologia , Hemodinâmica , Homeostase , Humanos , Masculino , Pessoa de Meia-Idade , Acidente Vascular Cerebral/fisiopatologia
6.
Neurophotonics ; 6(2): 020401, 2019 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-31093513

RESUMO

We offer a retrospective report on fNIRS 2018, along with news of the next meeting.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...